1PosSSI/Analog
6
6.1 Product Overview
Order number
6ES7138-4DK00-0AB0
Features
Positioning module for controlled positioning using the analog output
Switchover and switch-off difference can be set using your control program
The voltage for rapid and creep feed, acceleration, and deceleration can be set using
your control program
SSI Encoder
13-bit Singleturn
25-bit Multiturn
Usable axis types
Linear axis
Rotary axis
Operating range: 0 - 16 777 215 steps
The drive is controlled using the analog output
± 10 V, digital output DO can be controlled freely
0 V to 10 V, direction using digital output DO
3 digital inputs can be used for the following:
Minus hardware limit switch
Plus hardware limit switch
Reducing cam/latch input
Diagnostics
Encoder monitoring
Configuration
To configure the 1PosSSI/Analog, you can use either
A DDB file (http://www.ad.siemens.de/csi/gsd) or
STEP 7 as of V5.1 SP2.