1PosInc/Analog
4.6 Functions of the 1PosInc/Analog
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
139
Execution of a Reference Point Run Depending on Parameterization and Start Position
In a reference point run, you have to distinguish between different cases that depend on the
following:
The start position of the drive at the start of the reference point run
The assigned parameter start direction
The assigned parameter reference signal
The assigned parameter reference switch.
Example 1: Search for Reference Point Run with Reducing Cam and Zero Mark
Start position: between the minus limit switch and the reducing cam
Start direction: Plus
Reference signal: Reference switch and zero mark
Reference switch: Reduction cam towards plus
6<1&
5DSLGIHHG
&UHHSIHHG
6WDUWSRVLWLRQ
=HURPDUN
5& UHGXFLQJFDP
5&
Figure 4-13 Search for Reference Point Run with Reducing Cam and Zero Mark
You can also carry out synchronization using the reducing cam without a zero mark.
If the start position is on the reducing cam, the 1PosInc/Analog controls the drive directly in
creep feed mode in the referencing direction.