1PosSSI/Analog
6.8 Parameter List
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
299
Parameters Meaning Value range Default setting
Drive
Adapt direction If you adjust the direction, this results
in the polarity reversal of your drive
Off
On
Off
Function DO Output:
Your drive is controlled by the analog
output using ±10 V.
You control the OUT digital output
using the CTRL_DO control bit.
Direction:
Your drive is controlled by the analog
output using 0 V to +10 V.
The direction for your drive is set by
the 1PosSSI/Analog using the OUT
digital output.
Plus direction: OUT=1
Minus direction: OUT=0
Output
Direction
Output
Switch-off Use this parameter to determine the
course of the voltage after the
switch-off point.
Directly: The voltage is set directly to
0 V at switch-off point.
Ramp: As of switch-off point, voltage
is reduced to 0 V using the ramp.
Directly
Ramp
Directly
Switch-off difference Defines the distance from the
destination at which the drive is
slowed down from creep feed to 0.
If the switch-off difference ≥ the
switchover difference, there is no
switchover point. There is no
slowdown from rapid feed to creep
feed.
0 - 65 535 100
Switchover difference Defines the distance from the
destination at which the drive is
slowed down from rapid feed to
creep feed.
0 - 65 535 1000
Acceleration T
acc
in ms Time required for a change in
voltage via a ramp from 0 V to10 V.
At 0 ms acceleration is without a
ramp.
0 - 65 535 10000
Deceleration T
dec
in ms Time required for a change in
voltage via a ramp from 10 V to 0 V.
At 0 ms deceleration is without a
ramp.
0 - 65 535 10000