EasyManua.ls Logo

Siemens SIMATIC ET 200S - Page 85

Siemens SIMATIC ET 200S
382 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1PosInc/Digital
3.6 Functions of the 1PosInc/Digital
ET 200S Positioning
Operating Instructions, 05/2007, A5E00124871-04
85
Control Signals: Relative Positioning
Address Assignment
Bits 0.7 to 0.4:
7 6 5 4 Bit
0 1 0 0
MODE 4 = Relative Positioning
Byte 0
Bit 3: SPEED (SPEED = 0 is creep feed; SPEED = 1 is rapid feed)
Bit 2: DIR_M
Bit 1: DIR_P
Bit 0: START
Bytes 1 to 3 Distance
(linear axis: 0 to 16 777 215; rotary axis: 0...16 777 215)
Feedback Signals: Relative Positioning
Address Assignment
Byte 0 Bit 3: SYNC
Bit 2: POS_ DONE
Bit 1: POS_ERR
Bit 0: POS_ACK
Bytes 1 to 3 Actual value
(linear axis: 0 to 16 777 215; rotary axis: 0 to end of rotary axis - 1)
Parameters: Relative Positioning
Parameters Meaning Value range Default setting
Drive
Switch-off difference You can change the switch-off
difference with JOB 3.
0 - 65 535 100
Switchover
difference
You can change the switchover
difference with JOB 4.
0 - 65 535 1000

Table of Contents