Controlling the motor,200
Converter
does not respond,418
Update,417
Conveyor belt,127, 135, 142, 149, 326
Conveyor systems,148
Copy
Series commissioning,270
Copy parameters (series commissioning),270
Counter-clockwise rotation,200
Crane,247
Crushers,127, 135, 142, 149
cUL-compliant installation,77
Current input,194
Current reduction,432
Cyclic communication,228
D
Data backup,165, 173
Data transfer,172
Data set 47 (DS),231
Data set changeover,268
DC braking,216, 326, 327, 328, 329
DC link overvoltage,344
DC link voltage,344
Deadband,197
Delta connection,81
Delta connection (Δ),121
Derating
Installation altitude,432
Pulse frequency,432
Temperature range,434
Voltage,435
Derating as a function of the pulse frequency,432
Digital input,89, 200
Digital inputs
Multiple assignment,268
Digital output,89
Function,192, 195, 198
Dimension drawings,46, 50, 57, 59, 63
DIP switch
Analog input,194
Direct data exchange,231
Direction of rotation,279
Direction reversal,200
Discrepancy,262
Filter,262
Tolerance time,262
Drilling pattern,46, 54, 57, 59, 63
Drive control,183
Drive Data Set, DDS,359
Drive Data Sets,359
Dynamic braking,332
E
Electromechanical sensor,103
Elevator,247
EMC,39
EMERGENCY OFF,257
EMERGENCY STOP,257
Emergency Stop button,256
EN60204‑1,257
EN61800-5-2,256
End position,242
End position control,242
Energy-saving display,357
Extending the telegram,229
Extruder,127, 135, 142, 149
F
Factory assignment,89
Factory settings,153
Restoring the,153, 154, 156
Failsafe digital input,190
Fan,127, 135, 142, 148, 149
Fans,337
Fault,361, 369
Acknowledge,369, 370
Motor,419
Fault bu󹪜er,369
Fault case,371
Fault code,369
Fault history,370
Fault time,369
received,369
removed,369
Fault value,369
FCC,300
FCC (Flux Current Control),302
F-DI (Failsafe Digital Input),190
F-digital output module,104
Field weakening,81
Fieldbus interfaces,82, 109
Filter
Contact bounce,263
Discrepancy,262
On/o󹪜 test,263
Firmware
Update,417
Firmware downgrade,414
Index
SINAMICS G120C Converters
470 Operating Instructions, 02/2023, FW V4.7 SP14, A5E34263257B AK

Table of Contents

Other manuals for Siemens SINAMICS G120C DP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C DP and is the answer not in the manual?

Siemens SINAMICS G120C DP Specifications

General IconGeneral
Protection RatingIP20
Frequency Range0 to 650 Hz
Control ModesV/f, sensorless vector control
Communication InterfacesPROFIBUS DP
Ambient Temperature-10 to +50 °C (without derating), -10 to +60 °C (with derating)
Overload Capacity150 % rated current for 60 s, 200 % rated current for 3 s
Storage Temperature-40 to +70 °C
Relative Humidity5% to 95% (non-condensing)
Voltage Range200 V to 240 V (±10%), 380 V to 480 V (±10%)
Output Voltage0 V to Supply Voltage