Order Code Meaning Description
17 COAS Coasting to stop The drive is not controlling the motor and it is coasting to a stop due only
to friction.
18 TUNE Auto Tuning The drive is in a "Auto Tuning" mode used to determine motor character‐
istics.
19 FALT Drive fault active This mode is selected if any drive fault exists, but is not usually displayed
as the fault message is displayed instead. This is shown if the "Fault display
override" (8200) feature is enabled.
9.1.13 Adjusting the SIMATIC KTP700 HMI Display Brightness
To adjust the KTP700 display brighness, perform the following steps as indicated below:
1. Ensure that NXG control power is ON. The drive MODE must be NOMV, INH, or OFF.
2. Start at the NXG Main Screen with the touch keypad displayed.
Figure 9-20 NXG Main Menu Screen - touch keypad displayed
Software user interface
9.1 SIMATIC Keypad
NXGPro+ Control Manual
362 Operating Manual, A5E50491925A