Menu ID Submenu Names ID Table Description
Stability Menu 3 Input processing 3000 Input Processing Menu Adjust the VFD's vari‐
ous control loop gains,
including current and
speed regulator gains.
Output processing 3050 Output Processing Menu
Control loop test 3460 Control Loop Test Menu
Auto Menu 4 Speed pro󹪝le 4000 Speed Pro󹪝le Menu Con󹪝gure various
speed setpoint, pro󹪝le,
critical speed avoid‐
ance and comparator
parameters.
Analog inputs 4090 Analog Input Menu
Analog outputs 4660 Analog Outputs Menu
Speed setpoints 4240 Speed Setpoint Menu
Incremental speed setup 4970 Incremental Speed Setup Menu
PID select 4350 PID Select Menu Set up PID parameters.
Comparator setup 4800 Comparator Setup Menu Con󹪝gure the analog
comparators control‐
led through the SOP.
Main Menu 5 Motor 1 Motor Menu Access menus directly
from the keypad.
Drive 2 Drive Menu
Stability 3 Stability Menu
Auto 4 Auto Menu
Logs 6 Logs Menu
Drive protect 7 Drive Protect Menu
Meter 8 Meter Menu
Communications 9 Communications Menu
Security edit functions 5000 Security Edit Functions Menu Con󹪝gure security fea‐
tures.
Logs Menu 6 Event log 6180 Event Log Menu Con󹪝gure and inspect
the event, alarm or
fault, and historic logs
of the VFD.
Alarm/fault log 6210 Alarm/Fault Log Menu
Historic log 6250 Historic Log Menu
Drive Protect Menu 7 Input protection 7000 Input Protect Menu Adjust set point limits
for critical VFD varia‐
bles.
Meter Menu 8 Display parameters 8000 Display Parameters Menu Set up variables for dis‐
play to LCD.
Hour meter setup** 8010 Hour Meter Setup
Input harmonics 8140 Input Harmonics Menu
Fault display override* 8200 Meter Menu
Communications
Menu
9 Serial port setup 9010 Serial Port Setup Menu Con󹪝gure the various
communications fea‐
tures of the VFD.
Network control 9943 See Communications Manual
Network 1 con󹪝gure 9900
Network 2 con󹪝gure 9914
Display network monitor* 9950 Communications Menu
Serial echo back test* 9180 See Communications Manual
Sop & serial functions 9110 Serial Functions Menu
TCP/IP setup 9300 TCP/IP Setup Menu