Table 6-35 Internal Analog Input 11 Menu (2725) Parameters
Parameter ID Unit Default Min Max Description
Type 2726 1 Set the operational mode for internal AI11:
0 to 20 mA
4 to 20 mA
0 to 10 V
RTD
Hardware Zero 2727 0 -200 200 Internal analog input 11 zero
Hardware Span 2728 1 0.75 1.25 Internal analog input 11 span
RTD Alpha Value 2107 0.39 0.1 0.7 Set the internal I/O RTD's analog input alpha
value.
Table 6-36 Internal Analog Input 12 Menu (2731) Parameters
Parameter ID Unit Default Min Max Description
Type 2732 1 Set the operational mode for internal AI12:
0 to 20 mA
4 to 20 mA
0 to 10 V
RTD
Hardware Zero 2733 0 -200 200 Internal analog input 12 zero
Hardware Span 2734 1 0.75 1.25 Internal analog input 12 span
RTD Alpha Value 2108 0.39 0.1 0.7 Set the internal I/O RTD's analog input alpha
value.
Internal Analog Output Menus
Table 6-37 Internal Analog Output 1 Menu (2845) Parameters
Parameter ID Unit Default Min Max Description
Analog variable 2846 1 Internal analog output 1 source pick list.
See Pick list for Internal Analog Output Source.
Output Mode 2848 0 Internal analog output 1 mode:
4 to 20 mA
0 to 20 mA
Output Min 2841 % 0 -300 300 Internal analog output 1 minimum
Output Max 2842 % 100 -300 300 Internal analog output 1 maximum
Hardware Zero 2843 0 -200 200 Internal analog input 1 zero
Hardware Span 2844 1 0.75 1.25 Internal analog input 1 span
Output Default 2849 % 0 0 100 Analog output 1 watchdog default value