6.6 Options for Drive Menu (2) - second part
Internal I/O Submenus
The Internal I/O Menu (2805) consists of the parameters and submenus listed below. Contents
of these submenus are explained in the tables that follow.
Table 6-20 Internal I/O Menu (2805) Parameters
Parameter ID Unit Default Min Max Description
Set Module Ad‐
dresses
2819 Function Fix internal I/O "old module address not same as new" er‐
rors.
Watchdog timeout 2821 sec 0.01 0.01 10 Set the internal I/O watchdog timeout period.
Module 1 2806 Submenu Access the setup menu for internal I/O module 1.
See Table Internal I/O Module 1 Menu (2806).
Module 2 2807 Submenu Access the setup menu for internal I/O module 2.
See Table Internal I/O Module 2 Menu (2807).
Module 3 2808 Submenu Access the setup menu for internal I/O module 3.
See Table Internal I/O Module 3 Menu (2808).
Module 4 2809 Submenu Access the setup menu for internal I/O module 4.
See Table Internal I/O Module 4 Menu (2809).
Table 6-21 Internal I/O Module 1 (2806) Parameters
Parameter ID Unit Default Min Max Description
Module Type 2801 0 0 2 Set the type for internal I/O module 1. 0 = no
module installed.
Voltage 2561 V 120 -200 200 Set the required module voltage. Possible op‐
tions are:
24 V
120 V
Int Analog In1 2815 Submenu Access the setup menu for internal analog in‐
put 1.
See Table Internal Analog Input 1 Menu (2815).
Int Analog In2 2825 Submenu Access the setup menu for internal analog in‐
put 2.
See Table Internal Analog Input 2 Menu (2825).
Int Analog In3 2835 Submenu Access the setup menu for internal analog in‐
put 3.
See Table Internal Analog Input 3 Menu (2835).
Int Analog Out1 2845 Submenu Access the setup menu for internal analog out‐
put 1.
See Table Internal Analog Output 1 Menu
(2845).
Int Analog Out2 2855 Submenu Access the setup menu for internal analog out‐
put 2.
See Table Internal Analog Output 2 Menu
(2855).
Parameter Assignment/Addressing
6.6 Options for Drive Menu (2) - second part
NXGPro+ Control Manual
Operating Manual, A5E50491925A 113