4.1 CNC operator panel (PCU) interfaces
Interfaces
4-20
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
4.1.2 Ethernet interface
A PG/PC can be connected to the Ethernet interface via a Fast Ethernet network. The
device connected must possess an Ethernet card and the appropriate software.
Industrial Ethernet is a communication network providing a transmission rate of
10/100 Mbps.
Female connector pin assignment
Designation: X7 (Ethernet)
Type: 8-pin RJ45 socket
Table 4-1 Pin assignment of female connector X5
Schematic view of the female connector,
mounting position and labeling
Pin Name Description
1
8
1 TXP Transmitted data +
2 TXN Transmitted data –
AB
3 RXP Received data +
X5
IE
4 not assigned –
5 not assigned –
6 RXN Received data –
7 not assigned –
8 not assigned –
You can obtain additional information about the different cable systems for Ethernet from your
SIEMENS contact person.
4.1.3 USB port (available soon)