A.1 List of machine data
Machine and Setting Data 802D
A-214
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
A.1.4 Axisspecific machine data
MD
number
MD identifier
Unit Brief description Activation
Display filter Attributes Data type
Default Dimension Default value Minimum value Maximum value Protection
System * Dimension Default value Minimum value Maximum value Protection
* Values other than those in the standard system
Note regarding the value definition:
TRUE corresponds to 1
FALSE corresponds to 0
30110 CTRLOUT_MODULE_NR
– Setpoint: Drive no./module no. POWER ON
–, – – BYTE
Default 1 1, 2, 3, 4, 5, 6, 7, 8, 9, 10,
11, 12, 13, 14, 15, 16, 17,
18, 19, 20, 21, 22, 23, 24,
25, 26, 27, 28, 29, 30, 31
1 31 2/2
30120 CTRLOUT_NR
– Setpoint: Output to module POWER ON
EXP, – – BYTE
Default 1 1 1 3 2/2
30130 CTRLOUT_TYPE
– Setpoint output type POWER ON
–, – – BYTE
Default 1 0 0 3 2/2
30134 IS_UNIPOLAR_OUTPUT
– Setpoint output is unipolar POWER ON
– – BYTE
Default 1 0 0 2 2/2
30200 NUM_ENCS
– Number of encoders POWER ON
–, – – BYTE
Default – 1 0 1 2/2
30220 ENC_MODULE_NR
– Actual value: Drive no./measuring circuit no. POWER ON
–, –, – – BYTE
Default 1 1 1 31 7/2
30230 ENC_INPUT_NR
– Actual value: Input number on module/measuring circuit board POWER ON
–, –, – – BYTE
Default 1 1 1 3 2/2
30240 ENC_TYPE
– Actual value: Encoder type POWER ON
–, –, – – BYTE
Default 1 0 0 5 2/2
30270 ENC_ABS_BUFFERING
– Absolute encoder: Traversing range extension POWER ON
EXP, –, – – BYTE
Default 1 0 0 1 2/2