Commissioning
9.2 Turning on and booting the control system
9-83
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
9.2 Turning on and booting the control system
Procedure
S Check the system visually for:
– correct mechanical design and check that all electrical connections are performed
correctly.
– connected voltages
– connection of shielding and grounding.
S Connect the control system (booting in the normal mode)
Booting in the normal mode
When the control system is turned on, the boot sequence is displayed on the control system
with all its individual phases. Once the start screen of the user interface has appeared, the
booting sequence is completed.
Booting in the start-up mode
After POWER ON and once the operating system has been started, the word “SINUMERIK”
is displayed filling the whole screen. Once this word has disappeared, press the SELECT
key.
The START UP MENU is displayed. Use the arrow key to select an appropriate power-up/
start-up mode and press INPUT to confirm.
The modes specified in the START-UP MENU have the following meanings:
S normal startup
If this option is chosen, the control system will boot with the last machine data set and
the previously loaded programs.
S reload saved user data
If this option is chosen, the user data (machine data, programs, etc.) backed up to the
flash memory are accepted.
S start-up with default data (is only displayed if protection level 1 or 2 is set)
If this option is chosen, the control system will boot with default machine data.
S software update
In this case, the control system will not boot at all. The software can only be updated if a
CF card with a software update is inserted in the slot for the CF card.
S PLC stop
Select PLC Stop while the control system is booting if PLC Stop can not be triggered via
the user interface any more.
Siemens Automation Parts