10.2 Operating the control panel in STARTER (with the motor rotating)
Creating a Drive Project
10-140
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
10.2 Operating the control panel in STARTER (with the motor rotating)
This chapter shows you how to start the motor using the control panel function in the
STARTER commissioning tool. These steps include:
S Load the project into the drive unit.
S Operate the control panel.
Prerequisites
The following prerequisites must be fulfilled to operate the control panel in STARTER:
S The components as described above are assembled.
S The drive unit is turned on as prescribed.
S You have established a connection from the serial PPI interface of the control unit to a
PC/PG with PPI interface.
S A project has been created using the STARTER commissioning tool.
10.2.1 Loading the project into the drive unit
Loading the project into the drive unit
To load the project into the drive unit, proceed as follows:
1. If you have not yet created the project “Machine Tool V1_2” (created in Section 10.1.1)
in STARTER, open the project using the Project > Open menu.
2. To use the “control panel” function, you have to switch to ONLINE mode. To switch to
the ONLINE mode, click the function key Connect to target system (as shown in
Fig. 10-28).