4.2 MCPA module interfaces
Interfaces
4-28
SINUMERIK 802D sl Instruction Manual (BA), 05/2005 Edition
6FC5 397-0CP10-1BA0
4.2 MCPA module interfaces
Overview
The illustration below shows the MCPA module with its interfaces and the status display.
X1020
X1021
X2
X1
X701
X110
LED status display
1
1
10
10
Fig. 4-2 Position of the interfaces and of the status display on the MCPA module
Table 4-7 Interfaces
Interfaces Function
Interfaces to the MCP
X1 and X2
40-pin plug connectors for connecting the machine control panel (MCP)
I/O interface
X1020 and X1021
10-pin plug connectors for connection of the power supply and of the
digital inputs and ouptuts
Analog spindle connection
X701
9-pin D-Sub connector for connecting an analog spindle with directly
mounted spindle actual-value encoder (TTL)
Interface to the PCU
X110
48-pin plug connectors for connecting the MCPA module to the PCU
Assignment of the interface to the MCP
Designation: X1, X2
Type: 40-pin ribbon-cable connector