EasyManuals Logo

Siemens SINUMERIK Commissioning Manual

Siemens SINUMERIK
736 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #217 background imageLoading...
Page #217 background image
Tool management
6.2 Settings in the configuration file
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
211
ApplDataParamName8 = TC_MPPCS8
ApplDataParamName9 = TC_MPPCS9
ApplDataParamName10 = TC_MPPCS10
ApplDataParamIO1 = <EndOfList>
; ApplDataParamIO1 = Min:=-42, Max:=62
; ApplDataParamIO2 = Min:=-210, Max:=712
ApplDataParamSize = TC_MPPCS_UNIT
ApplDataParamSize1 = <EndOfList>
; ApplDataParamSize1=TC_MPPCS1_UNIT
; ...
; ApplDataParamSize10=TC_MPPCS10_UNIT
Parameterization of the individual magazine, tool and working offset lists
; From changes in the following sections it is possible to determine
; which data is to be displayed in the individual magazine, tool and
; working offset lists.
; [1_MagList], [2_MagList], [3_MagList],
; [1_ToolList], [2_ToolList], [3_ToolList],
; [1_ActList], [2_ActList], [3_ActList].
; In these sections you can determine the number of
; columns that are not moved (i.e. always visible) during
; horizontal navigation ("NrOfFixedColumns=") and the
; individual columns "1=...", "2=...", etc.).
; The column number (number in front of "=") can take a value
between
; 1 and 1000. The maximum number of columns in a
; list is around 90, although with 90 columns in a
; list the display speed will slow down and
; the user will have to scroll horizontally in order to be able to
; view all the columns, so as a general rule this limit is
; not reached.
; Gaps are allowed between the numbers in the sequence of
; column numbers.
; To disable a column predefined in mmc2\paramtm.ini,
; in the user\paramtm.ini you can
; add the corresponding entry with the value "<Empty>".
; Specify "...=<EndOfList>" to define the end of
; the list. This increases the speed when reading
; the INI files after starting tool management.
; Example for the syntax of a column-definition line:
; "2=TC_TP2,11,TC_TP2 ; WzIdent "2": Number of the entry
; for first "TC_TP2": determines which NC data in the list of
columns
; will be displayed. The character string TC_TP2 corresponds to an
; NCK variable, see programming manual.
; The specified character strings are described in paramtm.txt.
; New in Version P5:

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
InterfaceEthernet, PROFIBUS, PROFINET, USB
Programming LanguagesDIN/ISO
DisplayTFT color display
CompatibilitySiemens drives and motors
SoftwareSINUMERIK Operate
Control Unit TypeCNC (Computer Numerical Control)
Safety FunctionsIntegrated safety functions up to SIL 3/PLe

Related product manuals