2_FindResultHeadlineText = R2HL ; "Tools disabled"
2_FindCondition = TC_TP8 && 4
; Disabled=bit 3 (2 to the power of (3-1)=4)
2_FindResultAddColumnBtss = <empty>
2_FindResultAddColumnText = <empty> ; or R2AddCol
2_FindResultAddColumnDisplayedNumberOfCharacters=0
2_FindLimitedToCurMagazine=False
; "True", "False" (default); restricted to current magazine
; if called via magazine list.
2_ResultListType =0
; 0 = Standard list (default setting), 1 = loading list
2_ReactivatePositioningMode = 0
; 0: Do not position,
; 1: Ask the operator whether to position,
; 2: Always position (default setting)
3_FindSoftkeyText = F3SK ; "Load all"
3_FindResultHeadlineText = R3HL
; Unloading list for all loaded tools
3_FindCondition = A_TOOLMN > 0
; Magazine number of tool greater than 0
3_FindResultAddColumnBtss = <empty>
3_FindResultAddColumnText = <empty> ; or R3AddCol
3_FindResultAddColumnDisplayedNumberOfCharacters=0
3_FindLimitedToCurMagazine=False
; "True", "False" (default); restricted to current magazine
; if called via magazine list.
3_ResultListType =0
; 0 = Standard list (default setting), 1 = loading list
3_ReactivatePositioningMode = 1
; Positioning during Reactivate
; 0: Do not position, 1: Ask the operator whether to
; position, 2: Always position (default setting)
4_FindSoftkeyText = F4SK ; "Unload all"
4_FindResultHeadlineText = R4HL
; Loading list for all unloaded tools
4_FindCondition = A_TOOLMN == 0
; Magazine number of tool equal to 0
4_FindResultAddColumnBtss = <empty>
4_FindResultAddColumnText = <empty> ; or R4AddCol
4_FindResultAddColumnDisplayedNumberOfCharacters=0
4_FindLimitedToCurMagazine=False
; "True", "False" (default); restricted to current magazine
; if called via magazine list.
4_ResultListType =0
; 0 = Standard list (default setting), 1 = loading list
4_ReactivatePositioningMode = 1
; Positioning during Reactivate

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
InterfaceEthernet, PROFIBUS, PROFINET, USB
Programming LanguagesDIN/ISO
DisplayTFT color display
CompatibilitySiemens drives and motors
SoftwareSINUMERIK Operate
Control Unit TypeCNC (Computer Numerical Control)
Safety FunctionsIntegrated safety functions up to SIL 3/PLe

Related product manuals