EasyManuals Logo

Siemens SINUMERIK Commissioning Manual

Siemens SINUMERIK
736 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #237 background imageLoading...
Page #237 background image
Tool management
6.2 Settings in the configuration file
HMI Advanced (IM4)
Commissioning Manual, 03/2009, 6FC5397-0DP10-3BA0
231
>
language\patm_*.ini:
[ShortcutSoftKeysForMagSelect]
; Softkey text of magazine selection shortcut softkeys.
; Syntax: magIdent=ShortcutSoftkeyText
; Explanation: "magIdent": magazine ident like in $TC_MAP2 or
; in magazine configuration in application
; maintenance tool management.
; "ShortcutSoftkeyText": Softkey text, use double blank to
; indicate wordwrap.
; turret10 = "1-Turret10 <<" // Softkey text
; turret20 = "2-Turret20 <<" // Softkey text
; chain10 = "3-Chain10 <<" // Softkey text
; turret15 = "4-Turret15" // Softkey text
; chain20 = "5-Chain20" // Softkey text
Display location status of adjacent locations
In the list displays (magazine list, tool list, working offset list) of the HMI Advanced tool
management bits 8 to 16 of the magazine location status can now also be displayed,
including the 4 bits "left, right, top, bottom half location reserved".
The NC uses this data when "Adjacent location management" is activated.
The data largely correspond to the NC variable $TC_MPP4.
Until now, bits 1 to 8 of the magazine location status could be displayed in the lists; this
expansion now makes it possible to display bits 8 to 16 as well.
The magazine location status bits 8 to 16 can be displayed using the HMI Advanced
software; they cannot, however, be changed.
The HMI Advanced software contains a sample parameter assignment (paramtm.ini,
paramtm.txt) where display of the additional magazine location status bits is prepared but not
activated.
Parameterization
The parameter assignment of the status bit display as column in the individual list views for
list displays 1 to 3 (magazine list 1 to 3, tool list 1 bis 3, working offset list 1 to 3) is
accordingly expanded to include the nine status bits.
As was the case previously, the individual language-dependent letters for display in the HMI
Advanced tool management list displays can also be parameterized in the INI file as an
exception, e.g. if the machine operator wants to use different letters or there is no modified
language DLL for the locale.
Restrictions
The NC only uses the data "left, right, top, bottom half location occupied/reserved" if
"Adjacent location management" is activated. If "Adjacent location management" is not
activated in the NC, display can still be activated for the associated magazine location status
bits in the HMI Advanced tool management list displays but the displayed values will always
be "Bit not set".

Table of Contents

Other manuals for Siemens SINUMERIK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK and is the answer not in the manual?

Siemens SINUMERIK Specifications

General IconGeneral
InterfaceEthernet, PROFIBUS, PROFINET, USB
Programming LanguagesDIN/ISO
DisplayTFT color display
CompatibilitySiemens drives and motors
SoftwareSINUMERIK Operate
Control Unit TypeCNC (Computer Numerical Control)
Safety FunctionsIntegrated safety functions up to SIL 3/PLe

Related product manuals