Commissioning a system
1.2 User administration
PCU-Basesoftware (IM8)
Commissioning Manual, 03/2009, 6FC5397-1DP10-4BA0
13
Startup (2) tab Option Effect
"yes" The password is not case-sensitive.
Authentication: "manual" Authentication with user name and password
(manual)
"EKS" Authentication with EKS
"manual+EKS" Either authentication with user name and
password or with EKS
"HMI" tab
Figure 1-4 "HMI" tab
Table 1- 3 The default is marked in "bold".
"HMI" tab Option Effect
Program
Start: "yes" The HMI program is started.
"no" The HMI program is not started.
File: F:\mmc2\rngkrnl.exe Directory of the HMI program
Task bar autohide: "no" HMI program: Hide start task bar
"yes" HMI program: Show start task bar
Task bar on top: "no" HMI program: Start task bar in the
background