Service protocol
AG25, AG26 Date: 09.07.2018 Art. No. 88094 Mod. status 225/18 Page 105 of 109
9.5.2 Flow chart: Speed mode
The flow chart below illustrates the control in the rotational speed mode via service protocol
(see chapter 9: Service protocol).
Fig. 17: Flow chart speed mode service protocol
Acknowledge error
‘S11103‘ command
Start
Supply voltage On
Read status word
‘R’ command
Operation enabled
SW = 00xx 0000 x000 x000
Enter target speed
‘F0‘ command
Enable target speed
‘M‘ command
Target speed enabled
SW = 01xx x000 000x x000
Stop travel job
‘N‘ or ‘O‘ command
Change target speed
‘F0‘ command
Fault
Status word Bit 8 = ‘1‘
SW = System Status Word
x = bit can be ‘0‘ or ‘1‘