EasyManua.ls Logo

Siko AG25 - Current Limiting; Inching 2 Offset

Siko AG25
109 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EtherCAT®
AG25, AG26 Date: 09.07.2018 Art. No. 88094 Mod. status 225/18 Page 56 of 109
8.2.1.42 Current Limiting
This parameter determines the setting for limiting the motor current.
The setting of current limiting is indicated as percentage of the nominal current.
Object
2619h
Description
Current limiting
Access
rw
Data type
UNSIGNED8
Default
110
EEPROM
Yes
Value range
25 110 %
8.2.1.43 Inching 2 Offset
The inching speed in Inching operation 2 can be influenced via this parameter
Values are given as percentage of parameter V-Inch, Object 2609h.
Object
261Ah
Description
Inching 2 Offset
Access
rw
Data type
UNSIGNED8
Default
100
EEPROM
No
Value range
10 100 %

Table of Contents

Other manuals for Siko AG25

Related product manuals