Service protocol
AG25, AG26 Date: 09.07.2018 Art. No. 88094 Mod. status 225/18 Page 89 of 109
Chapter
starting with
page
Error memory
99
9.3 Parameters
9.3.1 Positioning
9.3.1.1 Target Value
Read command
E0
see chapter 9.8 ASCII command structure
Write command
F0±xxxxxxx
Description
see chapter 8.2.1.3 Target Value
9.3.1.2 Actual Position
Read command
Z
see chapter 9.8 ASCII command structure
Write command
read-only
Description
Decimal format
see chapter 8.2.1.79 Actual Position
Read command
W
see chapter 9.8 ASCII command structure
Write command
read-only
Description
Binary format
see chapter 8.2.1.79 Actual Position
9.3.1.3 Actual Rotational Speed
Read command
V
see chapter 9.8 ASCII command structure
Write command
read-only
Description
see chapter 8.2.1.80 Actual Rotational Speed
9.3.1.4 Calibration Value
Read command
E3
see chapter 9.8 ASCII command structure
Write command
F3±xxxxxxx
Description
see chapter 8.2.1.31 Calibration Value