1B-8 Emission Control Devices:
4) Check the resistance between the terminals of the
PAIR control solenoid valve.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Resistance ()
PAIR control solenoid valve resistance
18 – 22 at 20 – 30 °C (68 – 86 °F)
5) Reinstall the PAIR control solenoid valve. Refer to
“PAIR Control Solenoid Valve Removal and
Installation (Page 1B-6)”.
Crankcase Breather (PCV) Hose Inspection
B718H11206003
Inspect the PCV hose (1) for wear and damage.
If it is worn or damaged, replace the PCV hose with a
new one.
Check that the PCV hose (1) is securely connected.
Crankcase Breather (PCV) Hose / Cover /
Separator Removal and Installation
B718H11206009
Removal
1) Remove the throttle body. Refer to “Throttle Body
Removal and Installation in Section 1D (Page 1D-
9)”.
2) Remove the engine sprocket outer cover. Refer to
“Engine Sprocket Removal and Installation in
Section 3A (Page 3A-2)”.
3) Remove the regulator/rectifier bracket bolts and
move the regulator/rectifier assembly.
4) Remove the PCV hose (1).
5) Remove the crankcase breather (PCV) cover (2).
6) Remove the oil breather separator (3).
I718H1120035-01
1
I718H1120022-01
I718H1120036-01
1
I718H1120037-01
2
I718H1120011-02
3
I718H1120028-01