EasyManua.ls Logo

Suzuki GSF1250 - Page 218

Suzuki GSF1250
685 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1D-16 Engine Mechanical:
3) Connect the respective vacuum tester hoses to each
vacuum nipple on the throttle body.
4) Start the engine.
5) Set up the SDS tool. (Refer to the SDS operation
manual for further details.)
6) Click “Data monitor”.
7) Warm up the engine (Water temp. more than 80°
(176 °F)).
8) Click “Active control”.
9) Click “ISC air volume control” (2).
10) Click “ON” button (3) to fix the ISC air volume of four cylinders.
NOTE
When making this synchronization, be sure that the water temperature is within 80 – 100 °C (176 – 212
°F).
I718H1140389-01
I718H1140382-01
2
I718H1140384-01
“A”
“B”
3
I718H1140385-01
“A”: Engine speed: Approx. 1 200 rpm “B”: ISC valve position: Approx. 77 step