5 First steps
91
Pos: 92 /TD/Erst e Schritte/testo Saver is/Hardware erwei tern/04 Analogkoppler ei nbinden/00 Analogko ppler einsetzen @ 4\mod_1 248880773887_79. docx @ 46514 @ 3555 @ 1
5.14.8. Integrating Saveris analog coupler (optional)
Using a Saveris analog coupler, you can integrate a transmitter
with standardized current/voltage interfaces into the Saveris
measuring system and monitor it. The Saveris analog coupler
thereby enables the integration of additional parameters other than
temperature and humidity into the Saveris measuring system.
The integration of an analog coupler is performed in three steps:
1. Connect transmitter to analog coupler.
2. Connect analog coupler to the Saveris base.
3. Parameterize analog coupler.
Connecting transmitter to analog coupler
You can supply the transmitter with power via the analog coupler or
select a separate power supply.
The circuit diagrams can be found in the analog coupler startup
instructions which are delivered together with the analog coupler.
Connecting analog coupler to the Saveris base.
The analog coupler U1 is connected to the Saveris base like a
Saveris radio probe (see Connecting radio probe page 49)
The analog coupler U1E is started up and connected to the Saveris
base like a Saveris Ethernet probe (see Integrating Saveris
Ethernet probe (optional) page 73)
Parameterizing analog coupler with Startup Wizard
1. Under Start | All Programs | Testo click on Testo Saveris
Startup Wizard.
- The welcome dialogue of the startup wizard is shown.

Table of Contents

Other manuals for TESTO Saveris

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TESTO Saveris and is the answer not in the manual?

TESTO Saveris Specifications

General IconGeneral
Humidity Range0 to 100 %RH
Measurement ParametersTemperature, Humidity
Data TransmissionWireless
Alarm FunctionYes
Resolution0.1 °C, 0.1 %RH
Radio Frequency868 MHz, 915 MHz
Data StorageInternal memory, Cloud
Power SupplyBattery

Related product manuals