Page #204 background image
AND IFR,#16bit
6-47
AND IFR,#16bit Bitwise AND to Clear Pending CPU Interrupts
SYNTAX OPTIONS OPCODE OBJMODE RPT CYC
AND IFR,#16bit 0111 0110 0010 1111
CCCC CCCC CCCC CCCC
X 2
Operands
IFR Interrupt flag register
#16bit 16-bit immediate constant value (0x0000 to 0xFFFF)
Description Clear specific pending interrupts by performing a bitwise AND operation with
the IFR register and the 16-bit immediate value. The result of the AND
operation is stored in the IFR register:
IFR = IFR AND #16bit;
Note: Interrupt hardware has priority over CPU instruction operation in cases where the
interrupt flag is being simultaneously modified by the hardware and the instruction.
Flags and
Modes
None
Repeat This instruction is not repeatable. If this instruction follows the RPT
instruction, it resets the repeat counter (RPTC) and executes only once.
Example
; Clear the contents of the IFR register. Disables all
; pending interrupts:
AND IFR,#0x0000 ; Clear IFR register

Table of Contents