CMP loc16,#16bit
6-76
Example ; Calculate:
; if( VarA > 20 )
; VarA = 0;
CMP @VarA,#20 ; Set flags on (VarA − 20)
MOVB @VarA,#0,GT ; Zero VarA if greater then