EasyManua.ls Logo

Texas Instruments TMS320C28x - Page 412

Texas Instruments TMS320C28x
695 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOT ACC
6-255
NOT ACC Complement Accumulator
SYNTAX OPTIONS OPCODE OBJMODE RPT CYC
NOT ACC 1111 1111 0101 0101 X 1
Operands ACC Accumulator register
Description The content of the ACC register is replaced with its complement:
ACC = ACC XOR 0xFFFFFFFF;
Flags and
Modes
N After the operation, the N flag is set if bit 31 of the ACC is 1, else N is cleared.
Z After the operation, the Z flag is set if the ACC is zero, else Z is cleared.
Repeat This instruction is not repeatable. If this instruction follows the RPT
instruction, it resets the repeat counter (RPTC) and executes only once.
Example
; Complement the contents of VarA:
MOVL ACC,@VarA ; ACC = VarA
NOT ACC ; Complement ACC contents
MOVL @VarA,ACC ; Store result into VarA