ZAP OVC
6-395
ZAP OVC Clear Overflow Counter
SYNTAX OPTIONS OPCODE OBJMODE RPT CYC
ZAP OVC 0101 0110 0101 1100 1 − 1
Operands
OVC
overflow counter bits in Status Register 0 (ST0)
Description Clear the overflow counter (OVC) bits in Status Register 0 (ST0).
Flags and
Modes
OVC
The 6-bit overflow counter bits (OVC) are cleared.
Repeat This instruction is not repeatable. If this instruction follows the RPT
instruction, it resets the repeat counter (RPTC) and executes only once.
Example
; Calculate: VarD = sat(VarA + VarB + VarC)
ZAP OVC ; Zero overflow counter
MOVL ACC,@VarA ; ACC = VarA
ADDL ACC,@VarB ; ACC = ACC + VarB
ADDL ACC,@VarC ; ACC = ACC + VarC
SAT ACC ; Saturate if OVC != 0
MOVL @VarD,ACC ; Store saturated result into VarD