ERROR CODE and TROUBLESHOOTING
6 - 102
[CC51] Sideways adjustment motor (M2) abnormality
[CC52] Skew adjustment motor (M1) abnormality
* The [CC51] error will be displays when the [ED11] error occurs three times in succession or
during the initial operation.
MJ-1103/1104 (When MJ-6102 is installed)
Is there any paper remaining on the transport path?
È
ÆYES Remove the paper.
NO
Rotate the sideways adjustment motor (M2). Does it rotate smoothly?
È
ÆNO Fix the mechanism.
YES
Are the sideways deviation home position sensor (S3) and its wiring correct?
È
ÆNO Replace the sensor. Correct the wiring.
YES
Is the wiring between the hole punch control PC board (HP) and sideways adjustment motor
(M2) correct?
È
ÆNO Correct the wiring.
YES
1. Replace the punch sideways adjustment motor (M2).
2. Replace the hole punch control PC board (HP).
* The [CC52] error will be displays when the [ED10] error occurs three times in succession or
during the initial operation.
MJ-1103/1104 (When MJ-6102 is installed)
Is there any paper remaining on the transport path?
È
ÆYES Remove the paper.
NO
Rotate the skew adjustment motor (M1). Does it rotate smoothly?
È
ÆNO Fix the mechanism.
YES
Are the skew home position sensor (S2) and its wiring correct?
È
ÆNO Replace the sensor. Correct the wiring.
YES
Is the wiring between the hole punch control PC board (HP) and skew adjustment motor (M1)
correct?
È
ÆNO Correct the wiring.
YES
1. Replace the skew adjustment motor (M1).
2. Replace the hole punch control PC board (HP).