Telephone Button Programming
800 Series Programs
Strata CTX Programming - Part 3: Telephone Button Programming 6/04 13-95
Telephone Button
Programming
803-01 Device Connection
)%
, n,
+ROG
n = 1. None (default)
2. LAN
3. RS-232
1. Enter RS-232 for SMDR or SMDI devices or PCs. These devices
are connected to BSIS, RS-232 ports.
2. Enter LAN for CTX WinAdmin, ACD Server, and Attendant Console
PC. These devices are connected to the BECU Network Jack directly
or via a HUB or LAN.
803-02 Device Port Number
)%
, n,
+ROG
n = 1~4 (for RS-232)
1~9 (for LAN)
11 (for BLF Networking)
(default = 1)
1. SMDR and SMDI devices can be assigned to any BSIS, RS-232
Port: 1~4 (one port per device)..
2. LAN devices and PCs can be assigned to LAN logical Port (1~9)
according to their logical device number assignments as shown:
LAN Port1=device200
LAN Port2=device201
LAN Port3=device202
LAN Port4=device203
LAN Port5=device204
LAN Port6=device205
LAN Port7=device206
LAN Port8=device207
Table 13-40 Device Table
Logical
Device
Logical Device
Serial Number
Physical Device Define I/O
Logical
Device
Number
LAN PPP RS-232C
Smart
Media
SMDR 0--OK-100
CTI
0OK---200
1OK---201
2OK---202
3OK---203
4OK---204
5OK---205
6OK---206
7OK---207
8OK---208
SMDI
0OK-OK-300
1OK-OK-301
Table 13-39 Programs 801~803 (continued)
Button Sequence Value(s) Summary