Telephone Button Programming
800 Series Programs
13-96 Strata CTX Programming - Part 3: Telephone Button Programming 6/04
Table 13-41 Program 804
Button Sequence Value(s) Summary
804
RS232C Data
Assignment
,
+ROG
Use this screen to setup the RS-232 serial Ports on the BSIS
interface PCB.
804-00 BSIS Port
n,
+ROG
n = 1~4 (default = no value) Enter the BSIS PCB port number.
804-01 Port Speed
)%
, n,
+ROG
n = 1. 300
2. 1200
3. 2400
4. 4800
5. 9600 (default)
6. 19200
7. 38400
8. 57600
This is the data speed of BSIS port in bits per second (bps).
Note The total combined maximum speed of BSIS ports cannot
exceed 57,600 bps.
804-02 Port Parity
)%
, n,
+ROG
n = 1. None
2. Even
3. Odd (default)
This is the parity error checking methods used by the BSIS port.
804-03 Data Bits
)%
, n,
+ROG
n = 1. 7 Bits (default)
2. 8 Bits
This is the number of data bits used for each data block.
804-04 Flow Control
)%
, n,
+ROG
n = 1. None (default)
2. Flow
This is the type of flow control used between the BSIS port and the
SMDI or SMDR device. Must be set to “FLOW” in order for the CTX to
buffer call records.
804-05 Wait Timer
)%
, n,
+ROG
,
+ROG
n = 0~255
(default = 30 seconds)
Maximum time to wait for connection.
1. 0 means wait permanently
2. Timer value can be 1-255 seconds.