System Error Codes
Trunk Programming Error Codes
B-14 Strata CTX Programming - Part 4: Appendices 6/04
302
33
)%
The equipment number entered is out of the range.
33
)%
The ILG entered is out of the range.
33
)%
The entered OLG is out of the range.
48
)%
Dch position is not set to 16. When setting the time slot
pattern for a 2048 kbps interface, this value must be set to 16.
49
)%
The type of ILG or OLG entered in not an ISDN.
49
)%
The ILG or OLG entered does not exist in the system.
49
)%
When the equipment is moved, the number of the PCM
highway in the moved equipment is different from the current
equipment.
49 -
The ILG entered is not registered in the system.
FB which this error occur : FB03
49 -
The OLG entered is not registered in the system.
FB which this error occur : FB03
49
)%
When the card type is “PTU1F”, the protocol type entered
should be “Bellcore” or “Bellcore Northern Telecom”.
49
)%
When the card type is “PTU”, the protocol type entered is
“ETSI”.
49
)%
The card type is not “IPU-Q” when IP is selected.
49
)%
The card type is not “PTU” or “PTU1F” when TTC or QSIG is
selected.
49
)%
When the card type is “PTU1F”, the inputted D channel
position is not 16.
49
)%
D channel position must assign “0” when the card type is
“IPU-Q”.
49
)%
D channel position must not be assigned “0” when the card
type is notIPU-Q”.
50
)%
The T-Wait Timer can only be enabled if the Protocol is set to
National ISDN.
52
)%
The entered Channel Group conflicts with an existing ISDN
extension(s), etc.
54
)%
The quantity of lines, ISDN channels and PDNs entered
exceeds the number of ports licensed with this processor.
80
)%
The entered Channel Group number does not exist in the
system.
80
)%
An ISDN trunk cannot be assigned to the designated Shelf/
Slot/Circuit.
80
)%
The designated ILG does not exist in the system.
80
)%
The designated OLG does not exist in the system.
96
)%
The number of allowable Channel Groups has been
exceeded when a new ISDN trunk assignment is made.
Program Code
Occurred
FB
Sub-
parameter
Error Descriptions

Table of Contents

Other manuals for Toshiba Strata CTX28

Related product manuals