No Authentication:No authentication is used.
MD5 Authentication:The Message Digest Version 5 (MD5) hash function is used to
determine that the message is from a valid source.
SHA Authentication:The Secure Hash Algorithm (SHA) has function is used to
determine that the message is from a valid source.
11. In the User Authentication Password box, type a password for the user.
12. In the User Privacy Protocol list, select the privacy protocol to encrypt the contents of the
data. You can select from the following:
No Encryption:No encryption is used.
DES Encryption:The Data Encryption Standard (DES) algorithm is used to encrypt the
data.
AES Encryption:The Advanced Encryption Standard (AES) algorithm is used to encrypt
the data.
13. In the User Privacy Password box, type a password for the privacy protocol.
14. Click Apply.
Viewing MIB Information
You can download the device Management Information Base (MIB) and use a SNMP application to
view the information. The MIB is a collection of manageable entities of the device network element.
The S1800e series device sends a coldStart trap when it is initialized and sends the following Verint-
Specific SNMP traps:
Video Signal Loss edVinMediaStateAnalogNotif trap. This trap is generated if an analog video
input of an S1800e series device is disconnected or reconnected with the following information:
Input number (1 to 16 for S1816e and S1816e-SP, 1 to 8 for S1808e)
New state (0: not connected, 1: connected)
Dry Input State Change edDigitalinPinStateNotif trap. This trap is generated if the status of a
digital alarm dry contact input of the S1800e device has changed with the following information:
Input number (1 to 16 for S1816e and S1816e-SP, 1 to 8 for S1808e)
New state (0: not connected, 1: connected)
edVinCamtampOofAlarmStateNotif trap. This trap is generated if the Out Of Focus status of an
input has changed with the following information:
[0x00]= Not Out Of Focus
[0x01]= Out Of Focus
Perform the following steps:
1. Start the Web Interface.
2. From the tree, select Configuration >SNMP.
Setting the SNMP Properties
91
www.verint.com/video_solutions

Table of Contents

Other manuals for Verint Nextiva S1808e-A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Verint Nextiva S1808e-A and is the answer not in the manual?

Verint Nextiva S1808e-A Specifications

General IconGeneral
BrandVerint
ModelNextiva S1808e-A
CategoryMedia Converter
LanguageEnglish

Related product manuals