Upload the Configuration File
1. At the prompt to Initiate an Upload of Configuration File, enter Y (Yes - begin) or N (No -
cancel). The current setting appears in brackets—[N] in the following example.
>INITIATE AN UPLOAD OF CONFIGURATION FILE-YES(Y) OR NO(N)?
>[N]
>[
NOTE: The following instructions refer to the Microsoft Windows HyperTerminal program. Thesesteps
may vary for other communications programs.
2. At the top of the HyperTerminal window, shown below, click on Transfer, then on Send File.
3. In the Send File window, as shown above:
In the Filename box, enter the full path of the file to be uploaded—for example, C:\ac8_
conf.sav—or click on the Browse button to locate the file.
In the Protocol box, select Xmodem from the drop-down list.
Click on the Send button. (To close the window without sending the file, click on Close or
Cancel.)
4. When the transfer is complete, a confirmation message—“Upload Successful”—appears in the
Service Terminal Interface window and the Liebert AC8 reboots with the new configuration.
7.9.6 Setup Serv Ph Num - Enter Phone Number
The Service Phone Number (Serv Ph Num) is used for remote monitoring by Liebert Global Services. The
number is designed to allow remote monitoring services to connect to the Liebert AC8. All alarms will be
sent to this number. When an alarm occurs, this number is dialed before any of the four pager numbers.
To use the service phone number features, be sure to connect the phone line connector to a telephone
wall jack using an RJ11 cord, as described in Phone Line Connector on page28.