ALPHA/DELTA INSTALLATION & MAINTENANCE CHECKLIST
ALPHA/DELTA INSTALLATION AND MAINTENANCE
CHECKLIST
Checked Good Needs
Aenon
N/A
16� Loop Detector - Test
Verify that the ground loops have been occupied
and the gate responds correctly. Test the loop
occupaon with the type of vehicles that will be
using the gate. The loop detector sensivity should
be set as high as possible without false detecons.
Ensure loop phasing is correct.
17� Loop Inspecon
Ensure all of the ground loop path is covered with
sealant. Exposed areas should be resealed.
18� Accessory Device Programming
Program changes through the Kinec Installer
Menu for the accessory devices, installed as
appropriate for site requirements.
19� Close Timer
Set the close mer if required and record the
seng:
Default is 0.
20� IES Sensivity
Test IES sensivity and adjust if needed. Record
seng:
Default is 2.
21� Usage Class
Record Usage Class seng in Inial Setup menu:
22� Gate Speed
Record the Open Speed sengs:
Record the Close Speed sengs: