ALPHA/DELTA INSTALLATION & MAINTENANCE CHECKLIST
ALPHA/DELTA INSTALLATION AND MAINTENANCE
CHECKLIST
Checked Good Needs
Aenon
N/A
16� Loop Detector - Test
Verify that the ground loops have been occupied
and the gate responds correctly. Test the loop
occupaon with the type of vehicles that will be
using the gate. The loop detector sensivity should
be set as high as possible without false detecons.
Ensure loop phasing is correct.
17� Loop Inspecon
Ensure all of the ground loop path is covered with
sealant. Exposed areas should be resealed.
18� Accessory Device Programming
Program changes through the Kinec Installer
Menu for the accessory devices, installed as
appropriate for site requirements.
19� Close Timer
Set the close mer if required and record the
seng:
Default is 0.
20� IES Sensivity
Test IES sensivity and adjust if needed. Record
seng:
Default is 2.
21� Usage Class
Record Usage Class seng in Inial Setup menu:
22� Gate Speed
Record the Open Speed sengs:
Record the Close Speed sengs: