160
wallaceperimetersecurity.comPhone: 866.300.1110
TROUBLESHOOTING
Table 12. SmartDC Controller - Troubleshoong
Ref.
No�
Display Descripon
Possible Causes Soluons
Condion Alert, Error or Fault
39 FAULT 14
STUCK GATE
The SmartDC Controller
has tried 3 mes to
overcome a stuck
gate. The gate is non-
operaonal while this
fault is triggered.
Caused by broken gate
hardware or ice/snow
buildup.
1. Check and correct gate
hardware as required.
2. Press RESET to clear fault.
40 ERROR 1
DIRECTION
ERROR
The SmartDC Controller
has detected that
operator ran in the
wrong direcon.
Motor wiring. 1. Check motor wiring and
correct, as needed.
2. Press RESET to clear fault.
41 ERROR 3
HY5B FAILED
The SmartDC Controller
has detected a
communicaon error
with a HY5B vehicle
detector.
Caused by removal of HY5B
or lack of integrity of the
socket connecon. This
message will also indicate
which detector the alert
applies to: Exit Loop (ELD),
Inside Obstrucon Loop
(IOLD), Outside Obstrucon
Loop (OOLD), or Center
Loop (CLD)- (User Relay
22).
1. Press RESET.
2. Remove and re-install the
HY5B.
3. Replace the HY5B if needed.

Table of Contents