Operation
05251/A1
Winterthur Gas & Diesel Ltd.
3/ 3
2.2.2 Defective Exhaust Valve Control Unit
If the piston, or the slide rod in the VCU cannot move, shut off the VCU immediately.
See 05201, paragraph 2 Emergency Operation with Exhaust Valve Closed.
Note: With one or more VCU cut-out, you can operate the engine only at
decreased load.
1) Replace the defective VCU as soon as possible (see 05201 Start the VCU and
the Maintenance Manual 56121).
2.2.3 Hydraulic Pipe to Exhaust Valve
1) If a hydraulic pipe to the exhaust valve is broken, cut out the injection to the
related cylinder (see 05101, paragraph 1 Cut Out the Injection).
2) Replace the defective hydraulic pipe as soon as possible (see 05201,
paragraph 2.3. See also the Maintenance Manual 84601).
2014