4.10.2 Starting Air Shut-off Valve
1) On the valve unit E, remove the check valve 35-115HA. Make sure that the three
O-rings do not fall out of the valve.
2) In the LDU20, get the CONTROL LOC. Page, then select the button CTRL. TR.
to get control.
3) In the LDU20, get the USER PARAMETERS page, then select the button AIR
RUN (see 40022, paragraph 3.10 User parameters) and make sure that:
D The solenoid valves ZV7013C and ZV7014C are energized (use a
screwdriver or a magnet tester).
D In the valve unit E, control air comes out at each outer bore at the check
valve position.
4) Make sure that:
D The shut-off valve 30-4325_E0_1 is manually closed.
D No shut-down signals are released.
D The turning gear is disengaged.
5) In the LDU20, get the MAIN page.
6) Select the button ON/OFF to set the auxiliary blowers to off.
7) In the LDU20 MAIN page, select the button START AHD. Make sure that
Auxiliary Blowers Stopped is shown. No start command is released.
8) Select the button START AST and do steps 3 to 7 again.
9) Select the button ON/OFF to set the auxiliary blowers to on then:
a) Select START AHD and do steps 3 to 7 again.
b) Select START AST. and do steps 3 to 7 again.
The auxiliary blowers start and in the valve unit E, control air comes out of each outer
bore at the check valve position.
10) Make sure that the O-rings are in position in the check valve 35-115HA.
11) Install the check valve 35-115HA in the valve unit E.