Key to Fig. 1
1 Air vent manifold 18 Ball valve
2 Vent turbocharger outlet 19 Ball valve
3 Main engine 20 Leak gland box outlet
4 Cylinder cooling water drain outlet 21 SAC wash water outlet
5 Dry cleaning device (TC) 22 Oily water from SAC outlet
6 Vent crankcase outlet 23 Leak outlets (main engine)
7 Air for wash plant TC and SAC inlet 24 SAC condensate water outlet
8 SAC wash plant 25 Orifice
9 Dirty oil piston underside outlet 26 Sludge oil trap
10 Level switch (LS 4071A) 27 Sludge tank
11 Orifice
12 Condensate collector AL Air line from board system
13 Level switch (LS 4075A) AV Air vent
14 Scavenge air cooler BW Drain to bilge water tank
15 Water for wash plant SAC inlet FW from freshwater system
16 SAC Vent OW Drain to oil / water drain tank
17 Vent unit WD Drain to water drain tank
Drainage System and Wash-water Piping System