4.3 The Drive and Programming Modes
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 101
Start-Up Programming &
Operation
4
Verifying Parameter Changes: Verify Menu
The Verify Menu lists edited parameters from the Programming Mode or as a result of Auto-Tuning. The Verify Menu
helps determine which settings have been changed, and is particularly useful when replacing a drive. If no settings have
been changed, the Verify Menu will read “None”. The Verify Menu also allows users to quickly access and re-edit any
parameter settings that have been changed.
Note: The Verify Menu will not display parameters from the A1 group (except for A1-02, Control Method Selection) even if those
parameters have been changed from their default settings.
The following example is a continuation of the steps above. Here, parameter C1-02 is accessed using the Verify Menu,
and is changed again from 1.50 s to 2.50 s.
The steps below are an example of how to check the list of edited parameters:
12.
Press as many times as necessary to return to the initial display.
Step Display/Result
1. Turn on the power to the drive. The initial display appears.
2.
Press or until the display shows the top of the Verify Menu.
3.
Press to enter the list of parameters that have been edited from their original default settings.
If parameters other than C1-02 have been changed, use or to scroll until C1-02 appears.
4.
Press to access the setting value. Left digit flashes.
Step Display/Result
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
RSEQ
LREF
FWD FWD/REV
- MODE -
U1-01= 0.00%
U1-02= 0.00%
U1-03= 0.00A
DRV
Speed Ref (OPR)
Rdy
RSEQ
LREF
FWD FWD/REV
- MODE - PRG
Modified Consts
HELP DATA
FWD
Modified
X Parameters
C1-02 = 2.50sec
(0.0~600.00)
“1.50sec”
FWD
- VERIFY -
PRG
Decel Ramp 1
Rdy
Home DATA
FWD
C1-01=002.50sec
(0.0~600.00)
“1.50sec”
- VERIFY - PRG
Decel Ramp 1
Rdy
Home
DATA
SIEP_C710616_38F_5_0.book 101 ージ 015年11月9日 月曜日 午後3時36分