5.3 C: Tuning
182 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
C6: Carrier Frequency
C6-03: Carrier Frequency
Sets the carrier frequency.
C6-06: PWM Method
Determines how the drive should perform pulse width modulation.
Setting 0: 2-phase/3-phase conversion
Setting 1: 2-phase modulation
Setting 2: 3-phase modulation
Note: The drive rated output current is reduced with setting 2. Contact Yaskawa or a Yaskawa representative for details.
C6-09: Carrier Frequency during Rotational Auto-Tuning
Determines the carrier frequency while performing Rotational Auto-Tuning. Although this parameter rarely needs to be
changed, when overcurrent problems occur when Auto-Tuning a low impedance motor, it may be helpful to set C6-03 to
a high value before setting C6-09 to 1.
Setting 0: 5 kHz
Setting 1: Same value set to C6-03
C6-21: Inspection Operation Carrier Frequency
Sets the carrier frequency during Inspection Run.
Setting 0: Use the value set to C6-03
Setting 1: 2 kHz
C6-23: Carrier Frequency during Initial Motor Pole Search
Sets the carrier frequency when estimating the initial polarity.
Setting 0: 2 kHz
Setting 1: Use the value set to C6-03
C6-31: Carrier Frequency during Rescue Operation
Note: Available in drive software PRG: 7016 or later.
Sets the carrier frequency during Rescue Operation.
Setting 0: Use the value set to C6-03
Setting 1: 2 kHz
No. Parameter Name Setting Range Default
C6-03 Carrier Frequency 1.0 to 15.0 kHz Determined by o2-04
No. Parameter Name Setting Range Default
C6-06 PWM Method 0 to 2 0
No. Parameter Name Setting Range Default
C6-09 Carrier Frequency during Rotational Auto-Tuning 0 or 1 0
No. Parameter Name Setting Range Default
C6-21 Inspection Operation Carrier Frequency 0 or 1 1
No. Parameter Name Setting Range Default
C6-23 Carrier Frequency during Initial Motor Pole Search 0 or 1 0
No. Parameter Name Setting Range Default
C6-31 Carrier Frequency during Rescue Operation 0, 1 0