5.2 b: Application
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 171
■ b7-02: Droop Control Delay Time
Adjusts the responsiveness of Droop control. Reduce the setting if the reaction time is too long, and increase it if hunting
occurs.
◆ b8: Energy Saving
The Energy Saving function can significantly increase the efficiency of an IPM motor.
Note: The Energy Saving function should be used only with a Yaskawa IPM motor.
■ b8-01: Energy Saving Control Selection
Enables or disables the Energy Saving function.
Setting 0: Disabled
Setting 1: Enabled
■ b8-16: Energy Saving Control Constant (Ki)
Enter the Energy Saving value (Ki) as specified on the motor nameplate (for IPM motors only).
■
b8-17: Energy Saving Control Constant (Kt)
Enter the Energy Saving value (Kt) as specified on the motor nameplate (for IPM motors only).
No. Parameter Name Setting Range Default
b7-02 Droop Control Delay Time 0.03 to 2.00 s 0.05 s
No. Parameter Name Setting Range Default
b8-01 Energy Saving Control Selection 0 or 1 0
No. Parameter Name Setting Range Default
b8-16 Energy Saving Control Constant (Ki) 0.00 to 2.00 0.10
No. Parameter Name Setting Range Default
b8-17 Energy Saving Control Constant (Kt) 0.00 to 2.00 1.00