EasyManua.ls Logo

YASKAWA L1000A - Three-Phase 600 V Class Drives

YASKAWA L1000A
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.1 A: Initialization
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 165
Parameter Details
5
A2: User Parameters
A2-01 to A2-32: User Parameters 1 to 32
The user can select up to 32 parameters and assign them to parameters A2-01 through A2-32 to provide quicker access by
eliminating the need to scroll through multiple menus. The User Parameter list can also save the most recently edited
parameters.
Saving User Parameters
To save specific parameters to A2-01 through A2-32, set parameter A1-01 to 2 to allow access to all parameters, then
enter the parameter number to one of the A2- parameters to assign it to the list of User Parameters. Finally, set A1-01
to 1 to restrict access so users can only set and refer to the parameters saved as User Parameters.
A2-33: User Parameter Automatic Selection
Determines whether recently edited parameters are saved to the second half of the User Parameters (A2-17 to A2-32) for
quicker access.
Setting 0: Do not save list of recently viewed parameters.
Set A2-33 to 0 to manually select the parameters listed in the User Parameter group.
Setting 1: Save history of recently viewed parameters.
Set A2-33 to 1 to automatically save recently edited parameters to A2-17 through A2-32. A total of 16 parameters are
saved with the most recently edited parameter set to A2-17, the second most recently to A2-18, and so on. Access the
User Parameters using the Setup Mode of the digital operator.
No. Parameter Name Setting Range Default
A2-01 to A2-32 User Parameters 1 to 32 A1-00 to S6-16 Determined by A1-02
No. Parameter Name Setting Range Default
A2-33 User Parameter Automatic Selection 0 or 1 1
SIEP_C710616_38F_5_0.book 165 ージ 015年11月9日 月曜日 午後3時36分

Table of Contents

Other manuals for YASKAWA L1000A

Related product manuals