EasyManua.ls Logo

YASKAWA L1000A - D: Reference Settings

YASKAWA L1000A
522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.4 d: Reference Settings
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 183
Parameter Details
5
5.4 d: Reference Settings
The d parameters determine the speed of the elevator including the speed reference and Field Forcing settings for motor
response.
d1: Speed Reference
The d1 parameter group is used to set the speed reference. Switch the multi-function input contact terminals to create a
multi-step speed sequence using the various references set to the d1 parameters.
d1-01 to d1-08: Speed References 1 to 8
These parameters set speed references 1 through 8. Each of these speed reference values can be selected using digital
inputs programmed for multi-speed selection (H1- = 3, 4, 5).
Refer to Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on page 124 for details.
d1-18: Speed Reference Selection Mode
Sets the priority of the speed reference inputs.
NOTICE: Always turn off the RUN command before changing the setting of parameters d1-18 (Speed Reference Selection Mode),
b1-01 (Speed Reference Selection), or H1- (Multi-Function Digital Inputs). If the RUN command is on when changing any of these
settings, the motor may unexpectedly start running, and could result in injury.
Setting 0: Use multi-speed references d1-01 to d1-08
Up to eight separate preset speed references can be programmed to the drive using parameters d1-01 through d1-08 and
can be selected using binary coded digital inputs. When d1-18 is set to “0”, parameters d1-19 through d1-23 are not
displayed. Refer to Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on page 124 for details.
Setting 1: High speed reference has priority
Six different speeds (d1-19 to d1-23, d1-26) can be programmed to the drive and can be selected using dedicated digital
inputs. Each of the speed references set to d1-19 through d1-23 takes priority over the leveling speed set to d1-26. When
d1-18 is set to “1”, parameter d1-01 to d1-08 are not displayed. Refer to Separate Speed Inputs (d1-18 = 1 or 2) on
page 125 for details.
Setting 2: Leveling speed reference has priority
Six different speeds (d1-19 to d1-23, d1-26) can be programmed to the drive and can be selected using dedicated digital
inputs. The leveling speed reference in d1-26, however, takes priority over all other speed references when enabled via
one of the multi-function input terminals (H1- = 53). When d1-18 is set to “2”, parameters d1-01 to d1-08 are not
displayed. Refer to Separate Speed Inputs (d1-18 = 1 or 2) on page 125 for details.
Setting 3: Use multi-speed references d1-02 to d1-08, no speed selection stops the drive
Up to seven separate preset speed references can be programmed to the drive using parameters d1-02 through d1-08 can
be selected using binary coded digital inputs. When d1-18 is set to “3”, parameters d1-19 through d1-23 are not displayed.
Refer to Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on page 124 for details.
No. Parameter Name Setting Range Default
d1-01 to d1-08
<1> Setting units and the default setting are determined by parameter o1-03. Refer to Defaults and Setting Ranges by Display Unit Selection
(o1-03) on page 442 for details.
Speed Reference 1 to 8 0.00 to 100.00%
<1>
0.00%
<1>
No. Parameter Name Setting Range Default
d1-18 Speed Reference Selection Mode 0 to 3 0
SIEP_C710616_38F_5_0.book 183 ージ 015年11月9日 月曜日 午後3時36分