438 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
B.5 Defaults by Drive Model Selection (o2-04)
B.5 Defaults by Drive Model Selection (o2-04)
The following tables show parameters and default settings that change with the drive model selection (o2-04). Parameter
numbers shown in parenthesis are valid for motor 2.
Table B.4 200 V Class Drives Default Settings by Drive Model Selection
No. Name Unit Default Settings
Model CIMR-LU 20008 20011 20014 20018 20025 20033 20047 20060 20075
o2-04 Drive Model Selection Hex. 65 66 67 68 6A 6B 6D 6E 6F
E2-11 Motor Rated Output HP 2 3 4 5 7.5 10 15 20 25
C5-17 Motor Inertia
kgm
2
0.0068 0.0088 0.0158 0.0158 0.026 0.037 0.053 0.076 0.138
C6-03Carrier Frequency kHz888888888
E2-01
(E4-01)
Motor Rated Current A 6.2 8.5 11.4 14 19.6 26.6 39.7 53 65.8
E2-02
(E4-02)
Motor Rated Slip Hz 2.6 2.9 2.7 2.73 1.5 1.3 1.7 1.6 1.67
E2-03
(E4-03)
Motor No-Load Current A 2.8 3 3.7 4.5 5.1 8 11.2 15.2 15.7
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 1.997 1.601 1.034 0.771 0.399 0.288 0.23 0.138 0.101
E2-06
(E4-06)
Motor Leakage Inductance % 18.5 18.4 19 19.6 18.2 15.5 19.5 17.2 20.1
E2-10 Motor Iron Loss for Torque Compensation W 53 77 91 112 172 262 245 272 505
E3-08 Motor 2 Mid Output Frequency Voltage V 17.2 16.1 16.1 16.1 16.1 16.1 16.1 16.1 16.1
E3-10 Motor 2 Minimum Output Frequency Voltage V 10.3 8.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0
E5-02 Motor Rated Power HP 1.5 2.2 3 5 7.5 10 15 20 25
E5-03 Motor Rated Current A 8 11 14 14.6 20 29.3 37.9 53.2 65
E5-05 Motor Stator Resistance Ω 1.048 0.645 0.645 0.331 0.37 0.223 0.153 0.095 0.069
E5-06 Motor d-Axis Inductance mH 6.96 7.03 7.03 4.78 5.39 3.58 3.46 2.46 1.99
E5-07 Motor q-Axis Inductance mH 10.58 9.71 9.71 6.52 7.36 4.89 4.96 3.7 2.99
E5-09 Motor Induction Voltage Constant 1 mV/(rad/sec) 220.8 235.3 235.3 239.3 254.3 237 270 254.3 256.7
L8-02 Overheat Alarm Level °C 115 125 110 110 120 125 120 120 125
L8-06 Input Phase Loss Detection Level % 15.0 16.0 14.0 14.0 18.0 20.0 22.0 20.0 21.0
L8-35 Installation Method Selection 2 2 2222222
n5-02 Motor Acceleration Time s 0.166 0.145 0.145 0.154 0.168 0.175 0.265 0.244 0.317
n9-60 A/D Conversion Start Delay μsec 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0
SIEP_C710616_38F_5_0.book 438 ージ 015年11月9日 月曜日 午後3時36分