B.5 Defaults by Drive Model Selection (o2-04)
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 439
Table B.5 400 V Class Drives Default Settings by Drive Capacity
No. Name Unit Default Settings
– Model CIMR-LU – 20085 20115 20145 20180 20215 20283 20346 20415
o2-04 Drive Model Selection Hex. 70 72 73 74 75 76 77 78
E2-11 Motor Rated Output HP 30 40 50 60 75 100 125 150
C5-17 Motor Inertia
kgm
2
0.165 0.220 0.273 0.333 0.49 0.90 1.10 1.90
C6-03Carrier Frequency kHz88555522
E2-01
(E4-01)
Motor Rated Current A 77.2 105 131 160 190 260 260 260
E2-02
(E4-02)
Motor Rated Slip Hz 1.7 1.8 1.33 1.6 1.43 1.39 1.39 1.39
E2-03
(E4-03)
Motor No-Load Current A 18.5 21.9 38.2 44 45.6 72 72 72
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 0.079 0.064 0.039 0.03 0.022 0.023 0.023 0.023
E2-06
(E4-06)
Motor Leakage Inductance % 19.5 20.8 18.8 20.2 20.5 20 20 20
E2-10 Motor Iron Loss for Torque Compensation W 538 699 823 852 960 1200 1200 1200
E3-08 Motor 2 Mid Output Frequency Voltage V 16.1 16.1 16.1 16.1 13.8 13.8 13.8 13.8
E3-10 Motor 2 Minimum Output Frequency Voltage V 8.0 8.0 8.0 8.0 6.9 6.9 6.9 6.9
E5-02 Motor Rated Power HP 30 40 50 60 75 100 125 150
E5-03 Motor Rated Current A 76.4 103.5 133.1 149.4 181.6 181.6 181.6 181.6
E5-05 Motor Stator Resistance Ω 0.054 0.041 0.027 0.022 0.016 0.016 0.016 0.016
E5-06 Motor d-Axis Inductance mH 1.7 1.29 0.91 0.9 0.72 0.72 0.72 0.72
E5-07 Motor q-Axis Inductance mH 2.55 2 1.41 1.39 1.11 1.11 1.11 1.11
E5-09 Motor Induction Voltage Constant 1 mV/(rad/sec) 261.1 260.4 245.1 276 0.317 0.533 0.592 0.646
L8-02 Overheat Alarm Level °C 130 130 130 125 115 120 120 120
L8-06 Input Phase Loss Detection Level % 21.0 17.0 27.0 28.0 17 16 24 22
L8-35 Installation Method Selection – 22220000
n5-02 Motor Acceleration Time s 0.355 0.323 0.32 0.387 0.317 0.533 0.592 0.646
n9-60 A/D Conversion Start Delay μsec 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0
No. Name Unit Default Settings
– Model CIMR-LU – 40005 40006 40007 40009 40015 40018 40024 40031
o2-04 Drive Model Selection Hex. 94 95 96 97 99 9A 9C 9D
E2-11 Motor Rated Output HP 2 3 4 5 7.5 10 15 20
C5-17 Motor Inertia
kgm
2
0.0068 0.0088 0.0158 0.0158 0.026 0.037 0.053 0.076
C6-03Carrier Frequency kHz88888888
E2-01
(E4-01)
Motor Rated Current A 3.1 4.2 5.7 7 9.8 13.3 19.9 26.5
E2-02
(E4-02)
Motor Rated Slip Hz 2.5 3 2.7 2.7 1.5 1.3 1.7 1.6
E2-03
(E4-03)
Motor No-Load Current A 1.4 1.5 1.9 2.3 2.6 4 5.6 7.6
E2-05
(E4-05)
Motor Line-to-Line Resistance Ω 1.01 6.495 4.36 3.333 1.595 1.152 0.922 0.55
E2-06
(E4-06)
Motor Leakage Inductance % 18.3 18.7 19 19.3 18.2 15.5 19.6 17.2
E2-10 Motor Iron Loss for Torque Compensation W 53 77 105 130 193 263 385 440
E3-08 Motor 2 Mid Output Frequency Voltage V 34.4 32.2 32.2 32.2 32.2 32.2 32.2 32.2
E3-10 Motor 2 Minimum Output Frequency Voltage V 20.6 16.0 16.0 16.0 16.0 16.0 16.0 16.0
E5-02 Motor Rated Power HP 1.5 2.2 3 5 7.5 10 15 20
E5-03 Motor Rated Current A 4.8 5.5 7.2 7.3 10 14.6 19 26.6
E5-05 Motor Stator Resistance Ω 4.192 2.658 2.658 1.326 1.479 0.892 0.613 0.378
E5-06 Motor d-Axis Inductance mH 27.83 28.12 28.12 19.11 21.58 14.33 13.84 9.85
E5-07 Motor q-Axis Inductance mH 42.32 38.85 38.85 26.08 29.44 19.56 19.83 14.79
E5-09 Motor Induction Voltage Constant 1 mV/(rad/sec) 441.7 470.6 470.6 478.6 508.4 473.9 540 508.4
L8-02 Overheat Alarm Level °C 110 110 110 110 110 115 120 120
L8-06 Input Phase Loss Detection Level % 14.0 14.0 14.0 14.0 26.0 26.0 21.0 22.0
L8-35Installation Method Selection –22222222
n5-02 Motor Acceleration Time s 0.166 0.145 0.145 0.154 0.168 0.175 0.265 0.244
n9-60 A/D Conversion Start Delay μsec 14.0 14.0 14.0 14.0 14.0 14.0 14.0 14.0