4.2 Using the Digital Operator
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 93
Start-Up Programming &
Operation
4
4.2 Using the Digital Operator
Use the digital operator to enter Run and Stop commands, edit parameters, and display data including fault and alarm
information.
◆ Keys and Displays
Figure 4.1
Figure 4.1 Keys and Displays on the Digital Operator
No.
<1> The STOP key has highest priority. Pressing the STOP key will always cause the drive to stop the motor, even if an Up/Down command is
active at any external Up/Down command source. To disable the STOP key priority, set parameter o2-02 to 0.
<2> The LO/RE key can only switch between LOCAL and REMOTE when the drive is stopped. By default settings the LO/RE key function is
disabled. To allow using the LO/RE key for switching between LOCAL and REMOTE, set parameter o2-01 to 1.
Display Name Function
1
Function Key
(F1, F2)
The functions assigned to F1 and F2 vary depending on the currently displayed menu. The name of each func-
tion appears in the lower half of the display window.
2ESC Key
• Returns to the previous display.
• Moves the cursor one space to the left.
• Pressing and holding this button will return to the Speed Reference display.
3 RESET Key
• Moves the cursor to the right.
• Resets the drive to clear a fault situation.
4 RUN Key
Starts the drive in the LOCAL mode.
The Run LED
• is on, when the drive is operating the motor.
• flashes during deceleration to stop or when the speed reference is 0.
• flashes quickly, the drive is disabled by a DI, the drive was stopped using a fast stop DI, or an Up/Down
command was active during power up.
5 Up Arrow Key Scrolls up to display the next item, select parameter numbers, and increment setting values.
6 Down Arrow Key Scrolls down to display the previous item, select parameter numbers, and decrements setting values.
7STOP Key
<1>
Stops drive operation.
8 ENTER Key
• Enters parameter values and settings.
• Selects a menu item to move between displays.
9 LO/RE Selection Key
<2>
Switches drive control between the operator (LOCAL) and the control circuit terminals (REMOTE) for the
Run command and speed reference. The LED is on when the drive is in the LOCAL mode (operation from
keypad).
10 RUN Light Lit while the drive is operating the motor. Refer to page 96 for details.
11 LO/RE Light Lit while the operator is selected to run the drive (LOCAL mode). Refer to page 96 for details.
12 ALM LED Light Refer to ALARM (ALM) LED Displays on page 95.
LO
RE
F2F1
ESC
RUN STOP
ENTERRESET
ALM
DIGITAL OPERATOR JVOP-180