62 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
3.4 Terminal Block Configuration
3.4 Terminal Block Configuration
Figure 3.3 shows the different main circuit terminal arrangements for the drive capacities.
Figure 3. 2
Figure 3.3 Main Circuit Terminal Block Configuration
<1> Terminal board design differs slightly for models CIMR-LU20215 through 20415, 40180 through 40304, and 50099
through 50200.
R/L1 S/L2 T/L3
U/T1
V/T2 W/T3
3
+
1
+
CIMR-LU40075, 0091
R/L1
S/L2
T/L3
B1
B2
U/T1
V/T2
W/T3
1
+
CIMR-LU20085, 0115
CIMR-LU40045, 0060
CIMR-LU50032, 0041
R/L1 S/L2 T/L3
U/T1
V/T2 W/T3
3
+
1
+
CIMR-LU20145, 0180, 0215, 0283, 0346, 0415
CIMR-LU40112, 0150, 0180, 0216, 0260 ,0304
CIMR-LU50052, 0062, 0077, 0099, 0130, 0172, 0200
CIMR- LU20047
CIMR- LU40024, 0031, 0039
CIMR- LU50013, 0017, 0022, 0027
R/L1 S/L2 T/L3
U/T1
V/T2 W/T3
+3+1
R/L1 S/L2 T/L3
U/T1
V/T2 W/T3
+3+1
CIMR- LU20060, 0075
CIMR-LU20008, 0011, 0014, 0018
CIMR-LU40005, 0006, 0007, 0009
CIMR-LU50003, 0004, 0006
CIMR- LU20025, 0033
CIMR- LU40015, 0018
CIMR- LU50010
R/L1 S/L2 T/L3 B1 B2 U/T1 V/T2 W/T3
+1 +2
U/T1 V/T2 W/T3
+1 +2
R/L1 S/L2 T/L3
B1
B2
R/L1 S/L2 T/L3 U/T1 V/T2 W/T3
+1 +2
B1 B2
B1 B2
U/T1 V/T2 W/T3
+1 +2
R/L1 S/L2 T/L3
<1>
CIMR-LU40370
CIMR-LU40450, 0605
YEA_TMonly
SIEP_C710616_38F_5_0.book 62 ペー 2015年11月9日 月曜日 午後3時36

Table of Contents