E.3 User Setting Table
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 505
E.3 User Setting Table
Use the Verify Menu to see which parameters have been changed from their original default settings.
• The diamond below the parameter number indicates that the parameter setting can be changed during run.
• Parameter names in boldface type are included in the Setup Group of parameters.
No. Name
User
Setting
A1-00 Language Selection
A1-01 Access Level Selection
A1-02 Control Method Selection
A1-03 Initialize Parameters
A1-04 Password
A1-05 Password Setting
A2-01 to
A2-32
User Parameters, 1 to 32
A2-33 User Parameter Automatic Selection
b1-01 Speed Reference Selection
b1-02 Up/Down Command Selection
b1-03 Stopping Method Selection
b1-06 Digital Input Reading
b1-08
Up/Down Command Selection while in Programming
Mode
b1-14 Phase Order Selection
b2-08 Magnetic Flux Compensation Value
b4-01 Timer Function On-Delay Time
b4-02 Timer Function Off-Delay Time
b6-01 Dwell Speed at Start
b6-02 Dwell Time at Start
b6-03 Dwell Speed at Stop
b6-04 Dwell Time at Stop
b7-01 Droop Control Gain
b7-02 Droop Control Delay Time.
b8-01 Energy Saving Control Selection
b8-16 Energy Saving Control Constant (Ki)
b8-17 Energy Saving Control Constant (Kt)
C1-01 Acceleration Ramp 1
C1-02 Deceleration Ramp 1
C1-03 Acceleration Ramp 2
C1-04 Deceleration Ramp 2
C1-05 Acceleration Ramp 3 (Motor 2 Accel Time 1)
C1-06 Deceleration Ramp 3 (Motor 2 Decel Time 1)
C1-07 Acceleration Ramp 4 (Motor 2 Accel Time 2)
C1-08 Deceleration Ramp 4 (Motor 2 Decel Time 2)
C1-09 Fast Stop Ramp
C1-10 Accel/Decel Setting Resolution
C1-11 Accel/Decel Switching Speed
C1-12 Motor 2 Acceleration Time
C1-13 Motor 2 Deceleration Time
C1-15 Inspection Deceleration Ramp
C2-01 Jerk at Accel Start
C2-02 Jerk at Accel End
C2-03 Jerk at Decel Start
C2-04 Jerk at Decel End
C2-05 Jerk below Leveling Speed
C3-01 Slip Compensation Gain
C3-02 Slip Compensation Primary Delay Time
C3-03 Slip Compensation Limit
C3-04 Slip Compensation Selection during Regeneration
C3-05 Output Voltage Limit Operation Selection
C4-01 Torque Compensation Gain
C4-02 Torque Compensation Primary Delay Time
C4-03 Torque Compensation at Forward Start
C4-04 Torque Compensation at Reverse Start
C4-05 Torque Compensation Time Constant
C5-01 Speed Control Loop Proportional Gain 1
C5-02 Speed Control Loop Integral Time 1
C5-03 Speed Control Loop Proportional Gain 2
C5-04 Speed Control Loop Integral Time 2
C5-06 Speed Control Loop Primary Delay Time Constant
C5-07 Speed Control Loop Settings Switching Speed
C5-08 Speed Control Loop Integral Limit
C5-13 Speed Control Loop Proportional Gain 3
C5-14 Speed Control Loop Integral Time 3
C5-16 Speed Control Loop Delay Time during Position Lock
C5-17 Motor Inertia
C5-18 Load Inertia Ratio
C5-19
Speed Control Loop Proportional Gain Time during
Position Lock
C5-20 Speed Control Loop Integral Time during Position Lock
C5-50 Set Vibrational Frequency Filter
C6-03 Carrier Frequency
C6-06 PWM Method
C6-09 Carrier Frequency during Rotational Auto-Tuning
C6-21 Inspection Operation Carrier Frequency
C6-23 Carrier Frequency during Initial Motor Pole Search
C6-31 Carrier Frequency during Rescue Operation
d1-01 Speed Reference 1
d1-02 Speed Reference 2
d1-03 Speed Reference 3
d1-04 Speed Reference 4
d1-05 Speed Reference 5
d1-06 Speed Reference 6
d1-07 Speed Reference 7
d1-08 Speed Reference 8
d1-18 Speed Reference Selection Mode
d1-19 Nominal Speed
d1-20 Intermediate Speed 1
d1-21 Intermediate Speed 2
d1-22 Intermediate Speed 3
d1-23 Releveling Speed
d1-24 Inspection Operation Speed
d1-25 Rescue Operation Speed
d1-26 Leveling Speed
d1-27 Motor 2 Speed Reference
d1-28 Leveling Speed Detection Level
d1-29 Inspection Speed Detection Level
d6-03 Field Forcing Selection
d6-06 Field Forcing Limit
E1-01 Input Voltage Setting
E1-03 V/f Pattern Selection
E1-04 Maximum output speed
E1-05 Maximum Voltage
E1-06 Base Frequency
No. Name
User
Setting