B.3 Parameter Table
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 421
■ n9
:
Current Detection Adjustments
◆ o: Operator Related Parameters
The o parameters set up the digital operator displays.
■
o1: Digital Operator Display Selection
For more details on the digital operator displays, refer to Digital Operator Display Unit Selection on page 108.
No. (Addr.) Name Description Setting Page
n9-60
(64DH)
<4> Default setting is determined by the drive model (o2-04).
A/D Conversion Start Delay
Sets a delay time for starting the current signal A/D conversion. This value seldom needs to be
changed.
Default:
<4>
Min: 0.0 μs
Max: 40.0 μs
248
No. (Addr.) Name Description Setting Page
o1-01
(500H)
Drive Mode Unit Monitor
Selection
Switches the display after the power has been turned on. When using an LED operator, pressing
the up arrow key will display the following data: frequency reference → rotational direction →
output frequency → output current → output voltage → U1-.
(This is done by entering the 1 part of U1-. Certain monitors are not available in some
control modes.)
Default: 106 (Monitor
U1-06)
Min: 105
Max: 699
249
o1-02
(501H)
User Monitor Selection after
Power Up
o1-02 selects the information that is displayed when the power is turned on.
1: Speed reference (U1-01)
2: Direction
3: Output speed (U1-02)
4: Output current (U1-03)
5: User-selected monitor (set by o1-01)
Default: 1
Min: 1
Max: 5
249
o1-03
(502H)
Digital Operator Display Unit
Selection
Sets the units the drive should use to display the frequency reference and motor speed monitors.
0: 0.01 Hz
1: 0.01% (100% = E1-04)
2: r/min (calculated using the number of motor poles setting in E2-04, E4-04, or E5-04)
3: User-selected units (set by o1-10 and o1-11)
4: Elevator units 1 (speed in m/s, accel/decel rate and jerk in s)
5: Elevator units 2 (speed in m/s, accel/decel rate in m/s
2
, jerk in m/s
3
)
6: Elevator units 3 (speed in ft/min, accel/decel rate in ft/s
2
, jerk in ft/s
3
)
Default: 1
Min: 0
Max: 6
<21>
249
o1-04
(503H)
V/f Pattern Setting Units
0: Hz
1: r/min
Default:
<5>
Min: 0
Max: 1
250
o1-05
(504H)
LCD Contrast Control
Sets the brightness of the LCD operator (option).
Default: 3
Min: 0
Max: 5
250
o1-06
(517H)
<44>
User Monitor Selection Mode
0: 3 Monitor Sequential (Displays the next 2 sequential monitors)
1: 3 Monitor Selectable (o1-07 and o1-08 selected monitor is displayed)
Default: 0
Min: 0
Max: 1
250
o1-07
(518H)
<44>
Second Line Monitor Selection
Selects the monitor displayed on the second line.
Default: 102
Min: 101
Max: 699
250
o1-08
(519H)
<44>
Third Line Monitor Selection
Selects the monitor displayed on the third line.
Default: 103
Min: 101
Max: 699
250
o1-10
(520H)
User-Set Display Units Maximum
Val ue
These settings define the display values when o1-03 is set to 3.
o1-10 sets the display value that is equal to the maximum output frequency.
o1-11 sets the position of the decimal position.
Default:
<20>
Min: 1
Max: 60000
251
o1-11
(521H)
User-Set Display Units Decimal
Display
Default:
<20>
Min: 0
Max: 3
251
o1-12
(739H)
Length Units
0: Millimeter unit
1: Inch unit
Default: 0
Min: 0
Max: 1
251
CLV
CLV/PM
V/f OLV
All Modes
All Modes
All Modes
CLV
CLV/PM
V/f OLV
All Modes
All Modes
All Modes
All Modes
All Modes
CLV
CLV/PM
V/f OLV